Skip to main content

Kisaju, Kajiado CountyMon – Sat, 8 AM – 5 PM

Gaskets, gland packing and electrical safety matting

Gasket and jointing sheet, packing for valve and pump shafts, and tested insulating matting for work in front of live equipment.

Sealing is where plant downtime usually starts: a weeping flange, a gland that will not hold, a joint that fails at the first steam-up. We supply the jointing sheet and packing to put it right, graded by medium and temperature.

Alongside them, we supply insulating matting for the floor in front of live switchgear.

Typical applications

  • Flange and pipework jointing
  • Valve and pump shaft sealing
  • Steam, oil and chemical service
  • Switchroom and substation flooring
  • Maintenance and shutdown stock

Industries served

  • Power generation
  • Food processing
  • Chemical processing
  • Industrial plants
  • Manufacturing

By job

How the materials differ

Jointing sheet grades follow the medium
The metallic insert in Style 20 metallic reinforces it for steam and higher temperatures. Non-metallic suits general duty; Style 59 is for oils and Style 60 for acids and chemicals.
Packing grades follow the medium too
PTFE is typically chosen for chemical and food-processing duty, aramid for abrasive media, and graphited packing for steam and hot water. Tell us the medium and we will confirm the grade.
Matting is graded by voltage
Class 0 up to 1 kV working, Class 1 up to 7.5 kV, Class 2 up to 17 kV and Class 4 up to 36 kV, tested at 10, 20, 30 and 50 kV.

Choosing the right material

  1. For a gasket, tell us four things. The medium, the temperature, the pressure and the flange size. We confirm the grade and thickness against the maker's data.
  2. For packing, measure the stuffing box section. We stock 6–50mm square. Say whether it is a pump or a valve, and what it seals.
  3. For matting, find the highest voltage. Choose the class at or above the highest voltage in front of which someone will stand. Choosing an HV insulating matting class

Matching the seal to the medium

Sealing failures are rarely about quality — they are about the wrong grade in the wrong service. Gasket sheet is chosen by what is in the pipe and how hot it runs; gland packing by the medium at the shaft; insulating matting by the voltage it has to withstand. Pick on the medium first, then the temperature.

Style 20 metallic jointing sheet
Service: 500 – 650°C
Steam, oil and gas service and anywhere thermal cycling is severe. Reinforced with a stainless or carbon steel insert, which is what carries the temperature.
Style 20 non-metallic (red)
Service: General duty
Lower-temperature general flange and pipework sealing, where the medium is not aggressive and the cost of a metallic grade is not justified.
Style 59 / Style 60
Service: Oil / acid
Style 59 is the premium oil-resistant grade; Style 60 stands up to acid and aggressive chemicals. Choose on the medium, not the temperature.
Gland packing — PTFE / aramid / graphited
Service: By medium
Pump and valve shafts in steam, hot water, oils and process fluids. Square section 6–50mm, in 5 kg and 10 kg rolls. No service temperature is published — tell us the medium and shaft duty and we will confirm the grade.
HV insulating matting
Service: 1 – 36 kV working
Switchrooms and substation floors. Specified by ASTM D178 class: Class 0 is 1 kV maximum use, Class 1 is 7.5 kV, Class 2 is 17 kV, Class 4 is 36 kV, each factory-tested well above its rating.
Read more: High-voltage insulating matting: choosing a class
  • All four Superlite jointing grades come as 1500×1000mm sheet in seven thicknesses from 1.5 to 6mm, ready to cut to your flange pattern. Klingerit 1000 is stocked alongside them.
  • Asbestos rope, tape, cloth and millboard remain in the catalogue but are a restricted material requiring controlled handling. Ask before specifying them for new work.

Questions buyers ask

Which gasket sheet for a steam line?

The metallic Style 20 grade, rated 500–650°C, is the one we supply for steam and high-pressure flange joints. Tell us the pressure and flange size and we will confirm the thickness.

Which gland packing for chemical or food service?

PTFE is the usual choice where the medium is a chemical or a food product. Tell us the medium and temperature, and we will confirm whether the grade we hold suits it.

Which matting class do I need?

The class whose maximum working voltage is at or above the highest voltage in front of the mat: Class 0 up to 1 kV, Class 1 up to 7.5 kV, Class 2 up to 17 kV, Class 4 up to 36 kV.

Do you cut gaskets to size?

We supply jointing sheet in full 1500 × 1000mm sheets. Give us your flange sizes when you ask for a quotation and we will confirm what we can cut.

Build your shutdown list

Send us the flanges, pumps and valves on your next shutdown, with sizes and media, and we will quote the sheet and packing together.