Skip to main content

Kisaju, Kajiado CountyMon – Sat, 8 AM – 5 PM

Single Laminated PE Roof Insulation Foil One Side

  • Single laminated
  • 2 – 10mm
  • 40m & 50m rolls

The same closed-cell polyethylene core with foil on one face instead of two. It belongs where only one side will ever face an air gap — insulation laid against a deck, or over a ceiling where the void is on one side only.

Four sizes are held: 40m × 1.5m in 3mm and 5mm, and 50m × 1.2m in 2mm and 10mm.

Where both faces are open to air, the double laminated roll reflects in both directions and is the one to specify.

Request a QuoteAsk on WhatsApp

Prices are quoted, not published. What the price of roof insulation depends on, and what to send us.

Used for

  • Under metal roofing sheets
  • Ceiling voids with one open face
  • Container conversions and prefabs

Specifying this? Foil facing: vapour barrier or radiant barrier?

Request the technical data sheet for Single Laminated PE Roof Insulation — Foil One Side.

Roll of double-laminated reflective foil polyethylene roof insulation
Type
Single laminated, closed-cell PE core
Facing
Reflective foil, one face
Thickness
2, 3, 5 and 10mm
Widths
1.2m and 1.5m
Roll lengths
40m and 50m
R-value
Not published — ask

Thickness, width and roll length come from the stock list. No R-value or thermal conductivity figure is published for this material.

Sizes stocked

4 sizes on the stock list. Ask for anything not listed and we will quote to your specification.

Working out quantities? Use our insulation coverage calculator to see how many of these sizes cover your area.

  • 40m × 1.5m × 3mm
  • 40m × 1.5m × 5mm
  • 50m × 1.2m × 2mm
  • 50m × 1.2m × 10mm

About Single Laminated PE Roof Insulation — Foil One Side

Single or double

  • Foil reflects only at a face with air in front of it. A face laid flat against a deck does nothing.
  • One open face — single laminated. Both open — double laminated.
  • Paying for a second foil face you then bury is the common mistake; so is burying the only one you have.

What is not published yet

  • R-value or thermal conductivity.
  • Emissivity of the facing.
  • Fire classification.

Questions we get asked

Which way up does it go?
Foil face toward the air gap. If the gap is above, foil up; if below, foil down. If it hangs with air on both sides, the double laminated roll uses both; fit this one foil down there, because a face pointing up collects dust and dust dulls the foil. US Department of Energy guidance also fits single-sided foil face down. Laid the wrong way the foil is doing nothing and you have bought a bare foam core.
How many rolls do I need?
Both stocked roll sizes cover 60 m²: 40m × 1.5m (3 or 5mm) and 50m × 1.2m (2 or 10mm). Divide the roof area by 60 and round up, then allow for laps and cutting: 150 m² is 150 ÷ 60 = 2.5, so at least 3 rolls. The insulation coverage calculator on this site does the same sum for every stocked size.

Roll or board: which one?

GradeFacingChoose it for
Double Laminated Roof InsulationFoil both sidesRoofs where both faces are exposed to air, and anywhere radiant gain is the problem rather than conduction.
Single Laminated Roof InsulationFoil one sideOne face against a deck or a solid surface, the other open to an air gap.
PE Wall Insulation BoardWall boardWalls, where depth matters more than a reflective face.

Send us your material list

A specification, a BOQ or a photo of the label on the old stock is enough to start. We reply with an itemised quotation.

Or call or WhatsApp 0722 293 517